Maxtor 10K V User Manual

Page 181

Advertising
background image

Maxtor Atlas 10K V

5-123

0x04

Hdwe Error

0x06

0x90

Invalid CP18 on disk

0x06

0x91

Invalid CP21 on disk

0x06

0x92

Invalid CP22 in NVR

0x06

0x93

Head polarity cal failed.

0x06

0x94

Svo: Invalid head polarity vector in CP23

0x06

0x95

Seek 1 failure during servo writer erase band resync

0x06

0x96

Seek failure during ARCs Calibration

0x06

0x97

Seek failure during Pes Linearization

0x06

0x98

Error during Pes Lin bode measurement

0x06

0x99

Seek 2 failure during servo writer erase band resync

0x06

0x9A

Seek failure during pes linearization table update

0x06

0x9B

Motor speed error after turbo spin recovery

0x06

0x9C

Electrical offset calibration returned an invalid value

0x06

0x9D

Went servo dead during head polarity/coarse ATT cal.

0x06

0x9E

Data consistency failure during PES Linearization

0x06

0x9F

Couldn't find sync in the erase band & couldn't restart servo

0x06

0xA0

Went servo dead after completing a seek

0x06

0xA1

Successful sync not in the erase band

0x06

0xA2

ID GAMMA projected value out of range

0x06

0xA3

OD GAMMA calibration values out of range

0x06

0xA4

OD GAMMA projected value out of range

0x06

0xA5

Could not start estimator on printed media

0x06

0xA6

Too many spoke errors on printed media-1st

0x06

0xA7

Too many spoke errors on printed media-2nd

0x06

0xA8

Too much variation in position at crash stop

0x06

0xA9

Unable to determine a unique index

0x06

0xAA

Too much runout at the crash stop even with BCVs

0x06

0xAB

Crash stop position too large or too small

0x06

0xAC

Too much position runout at the crash stop

0x06

0xAD

Milli plant mag out of range

0x06

0xAE

Milli loop mag out of range

0x06

0xAF

Seek error for gamma frequency

0x06

0xB0

Seek error for FF Gain

0x06

0xB1

Cant find good track

0x06

0xB2

Servo Busy too long

0x09

0x00

Track following error

0x09

0x91

Svo:TA Err-1st

0x09

0x92

Svo:TA Err-2nd

0x09

0x93

Svo:Bad Sync-1st

0x09

0x94

Svo:Bad Sync-2nd

0x09

0x95

Svo: Offtrack Prediction Err-1st

Sense

Key

Sense

Code

Sense

Qualifier

Meaning

Advertising