9 electromagnetic conditions, 1 emi/rfi susceptibility, 2 esd – Maxtor 10K V User Manual

Page 57: 3 sensitivity to magnetic fields, 10 shock and vibration, Table 4-8 shock and vibration specifications

Advertising
background image

Maxtor Atlas 10K V

4-9

4.9

ELECTROMAGNETIC CONDITIONS

4.9.1

EMI/RFI Susceptibility

3 Volts/meter 80% modulated from 80 to 1000 MHz.

4.9.2

ESD

Drive must function with no data loss or component damage with air discharges
of 1 to 15 KV, and contact discharges of 2 to 8 KV in both positive and negative
voltages.

4.9.3

Sensitivity to Magnetic Fields

The Maxtor Atlas family of drives meet 3A @ 230V / 50 Hz specification.

4.10

SHOCK AND VIBRATION

The Maxtor Atlas 10K V hard disk drive can withstand levels of shock and
vibration applied to any of its three mutually perpendicular axes, or principal base
axis, as specified in Table 4-8. A functioning drive can be subjected to specified
operating levels of shock and vibration. When a drive has been subjected to
specified non-operating levels of shock and vibration, with power to the drive
off, there will be no change in performance at power on.

When packed in its 1-pack shipping container, the Maxtor Atlas 10K V drive can
withstand a drop from 42 inches onto a concrete surface on any of its surfaces,
six edges, or three corners. The 20-pack shipping container can withstand a drop
from 36 inches onto a concrete surface on any of its surfaces, six edges, or three
corners.

Table 4-8

Shock and Vibration Specifications

Note:

1. At ambient temperature and no unrecoverable errors.

PARAMETER

OPERATING

NON-OPERATING

Shock linear Half Sine
2 msec

1

Read/Write

63G/30G

1

250 G

1

Shock linear Half Sine
11 msec

1

15 G

1

100 G

1

Shock rotational
(rad/s

2

)

1

, 2 msec

7000

25,000

Vibration Swept

1

Vibration Random
(G

2

/Hz)

1.5G 0-p 5-500 Hz

0.008 10—300 Hz
0.0012 300—500 Hz

2.0G 0-p 5–500 Hz

0.014 10—300 Hz
0.01 300—500 Hz