Maxtor Atlas 10K V

5.11.2

LOG SENSE Log Pages

The log pages that are returned from the drive have a common format that is shown
in Table 5-43. Each page contains a 4-byte header followed by one or more log
parameters. Refer to Table 5-44. Table 5-45 contains the format for the Generic Log
Parameter and Table 5-46 describes the fields.

Table 5-43

LOG SENSE Log Page Format-Data Format

Note:

1

Length x or y is the sum of parameter header and parameter data

value bytes.

Table 5-44

LOG SENSE Log Page Format-Field Descriptions

Table 5-45

Generic Log Parameter-Data Format

Bit

Byte

7

6

5

4

3

2

1

0

0

Reserved

Page Code

1

Reserved

2 – 3

Page Length (n-3)

4 to

x+3

Log Parameter (first)

(length x)

1

n-y+1

to n

Log Parameter (last)

(length y)

1

Field

Description

Page Code

The page code as given in Table 5-39.

Page Length

The allocation length for the page minus the

4-byte header.

Log Parameter

One or more log data entities that are returned as par of

a Log Page. Each Log Parameter starts with a 4-byte

header followed by one or more bytes of value data. In

most cases, the parameter value is a 4-byte longword

that contains the present value of an error or perfor-

mance counter. See Table 5-45 for the format of a

generic log parameter.

Bit

Byte

7

6

5

4

3

2

1

0

0 – 1

Parameter Code

2

DU

DS

TSD

ETC

TMC

LBIN

LP

3

Page Length (n-3)

4 – n

Parameter Value