14 mode sense (6) command (1ah), Table 5-90 mode sense command-field descriptions – Maxtor 10K V User Manual

Page 123

Advertising
background image

Maxtor Atlas 10K V

5-65

5.14

MODE SENSE (6) Command (1Ah)

The MODE SENSE (6) command allows the initiator to read the drive's sector
descriptor and mode pages. The MODE SENSE Command Descriptor Sector is
shown in Table 5-89 and the data fields are described in Table 5-90. The Mode
Parameter Header is shown in Table 5-91 and the data fields are described in
Table 5-92.

Table 5-89

MODE SENSE (6) Command Descriptor Block-Data Format

Table 5-90

MODE SENSE Command-Field Descriptions

Table 5-91

Mode Parameter Header (6 Byte)-Data Format

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (1Ah)

1

Reserved

DBD

Reserved

2 PC

Page

Code

3

Sub Page Code

4

Allocation Length

5

Control

Data Field

Description

DBD

Disable Block Descriptor. When the value is 0, the drive returns its Block Descriptor

followed by the requested page(s). When the value is 1, the drive returns only the re-

quested pages.

PC

Page Control. Determines which type of page values are returned. These values are:

00b Current

01b Changeable

10b Default

11b Saved

Page Code

The Page Code field determines the pages to be returned to the initiator in the com-

mand's data-in buffer transfer. Refer to Table 5-49 and Table 5-93 for a complete list of

the Mode Pages (changeable and read-only). A Page Code of 3Fh causes all supported

pages to be returned.

Sub Page Code

The Sub Page Code field determines the sub pages to be returned to the initiator in the

command's data-in buffer transfer. A Sub Page Code of 0xFF causes all supported sub

pages to be returned.

Bit

Byte

7

6

5

4

3

2

1

0

0

Mode Data Length

1

Medium Type

2

Device-Specific Parameter

3

Block Descriptor Length

Advertising