Maxtor 10K V User Manual
Page 81
Maxtor Atlas 10K V
5-23
5.9.2.3
Implemented Operating Definition Page (81h)
The Implemented Operating Definition page reflects the current and available
operation definitions as described in Table 5-30 and Table 5-31.
Table 5-30
Implemented Operating Definition Page-Data Format
Table 5-31
Implemented Operating Definition Page-Field Descriptions
Bit
Byte
7
6
5
4
3
2
1
0
0
Peripheral Qualifier
= 0
Peripheral Device Type = 0
(Direct Access Device)
1
Page Code (81h)
2
Reserved
3
Page Length = 07h
4
Rsvd
Current Definition
5
SavImp
= 1
Default Definition is SCSI-2 U160 (04h)
6
SavImp
= 1
Supported-1 Definition is SCSI-3 U320 (06h)
7 *
SavImp
= 1
Supported-2 Definition is SCSI-3 U160 (05h)
8 SavImp
= 1
Supported-3 Definition is SCSI-2 U160 (04h)
9
SavImp
=1
Supported-4 Definition is SCSI-2 U80 (03h)
10
SavImp
=1
Supported-5 Definition is SCSI-1-CCS (02h)
Field
Definition
SavImp
Save Implemented. If = 0, this bit indicates that the
corresponding operation definition cannot be saved.
When = 1, this bet indicates that the corresponding
operating definition can be saved.