5.9.2.3

Implemented Operating Definition Page (81h)

The Implemented Operating Definition page reflects the current and available
operation definitions as described in Table 5-30 and Table 5-31.

Table 5-30

Implemented Operating Definition Page-Data Format

Table 5-31

Implemented Operating Definition Page-Field Descriptions

Bit

Byte

7

6

5

4

3

2

1

0

0

Peripheral Qualifier

= 0

Peripheral Device Type = 0

(Direct Access Device)

1

Page Code (81h)

2

Reserved

3

Page Length = 07h

4

Rsvd

Current Definition

5

SavImp

= 1

Default Definition is SCSI-2 U160 (04h)

6

SavImp

= 1

Supported-1 Definition is SCSI-3 U320 (06h)

7 *

SavImp

= 1

Supported-2 Definition is SCSI-3 U160 (05h)

8 SavImp

= 1

Supported-3 Definition is SCSI-2 U160 (04h)

9

SavImp

=1

Supported-4 Definition is SCSI-2 U80 (03h)

10

SavImp

=1

Supported-5 Definition is SCSI-1-CCS (02h)

Field

Definition

SavImp

Save Implemented. If = 0, this bit indicates that the

corresponding operation definition cannot be saved.

When = 1, this bet indicates that the corresponding

operating definition can be saved.