Maxtor 10K V User Manual

Page 128

Advertising
background image

5-70

Maxtor Atlas 10K V

Table 5-97

Rigid Disk Geometry Page-Field Descriptions (Page 4)

Field

Description

PS

Parameters Savable. This bit is only used with the MODE SENSE com-

mand. A returned value of 1 indicates that the target is capable of saving the

page in a non-volatile, vendor-specific location. The bit is reserved with the

MODE SELECT command.

Number of Cylinders

The number of physical cylinders that hold host data.

Number of Heads

The number of heads that can access host data.

Starting Cylinder

The value in this field is the physical cylinder at

Write

Precompensation

which write precompensation is to begin. The first cylinder number is 0. If

the starting cylinder is equal to the value in the Number of Cylinders field,

write precompensation is disabled.

Starting Cylinder

Reduced Write

Current

The value in this field is the physical cylinder at which write current is re-

duced. The first cylinder number is 0. If the starting cylinder for reduced

write current is equal to the value in the Number of Cylinders field, reduced

write current is disabled.

Drive Step Rate

Applies to stepper-motor actuators. Not applicable.

Landing Zone

Cylinder

This field indicates a two’s complement location where the drive positions

the disk heads. A negative value indicates that the heads are positioned be-

low cylinder 0 by that number of cylinders. A positive value greater than the

number of cylinders indicates that the heads are positioned beyond the cyl-

inders used for data storage at the location specified.

RPL

Rotational Position Locking is used for spindle synchronization in storage

arrays. The modes are:

00b – Disabled

10b – Master

01b – Slave

11b – Not supported

RPL can be overridden if the Maxtor (Vendor) Special Function Control

page Auto field value = 1. This drive does not support spindle synchroniza-

tion.

Rotational Offset

Rotational Offset indicates the amount of rotational offset that the drive

uses when synchronized. The rotational offset is applied in the retarded di-

rection (lagging the synchronized spindle master). The value in the field is

determined by the following formula:

Offset

= 0 … 255

256

For example, a numerator of 128 indicates an offset of 1/2 revolution

(180°).

The valid parameter values are 0 to 255.

The specified value may be rounded. Rotational offset is not used when the

drive is configured as the synchronized-spindle master.

Medium Rotation Rate

The disk rotation speed in RPM.

Advertising