Maxtor 10K V User Manual

Page 178

Advertising
background image

5-120

Maxtor Atlas 10K V

0x01

Rec

Error

0x17

0xA0

Possible Bump-1st - recovered

0x17

0xA1

Bump Err-2nd - recovered

0x17

0xA2

Defective Wdg-1st - recovered

0x17

0xA3

Defective Wdg-2nd - recovered

0x17

0xA4

Map'd Wdg-1st - recovered

0x17

0xA5

Map'd Wdg-2nd - recovered

0x17

0xA6

Id Err-1st - recovered

0x17

0xA7

Id Err-2nd - recovered

0x17

0xA8

Unknown Wdg Err-1st - recovered.

0x17

0xA9

Unknown Wdg Err-2nd - recovered

0x17

0xAA

Shock detected - recovered

0x17

0xAB

Shock Detected Err-2nd. - recovered

0x17

0xAF

Recovered data with ECC on-the-fly

0x17

0xB0

Confined sync timeout - recovered

0x17

0xB2

Context Acquire Timeout - recovered

0x17

0xB3

Context Acquire Data Addr Valid T/O - recovered

0x17

0xB5

False SSMF - recovered

0x18

0x00

Recovered data with ECC applied

0x18

0x02

Recovered data - data auto-reallocated

0x18

0x05

Recovered data - recommend reassignment (TA err)

0x18

0x85

Recovered data - thermal asperity error

0x1C

0x00

Requested Defect List Not Found

0x40

0x85

EDC check failed - recovered

0x40

0x86

Controller FIFO over/underflow error: recovered

0x40

0x8C

LBA mismatch error: recovered.

0x41

0x86

Required HW process did not complete: recovered

0x42

0x00

Power On or Self Test failed

0x5D

0x00

Smart triggered

0x5D

0x01

Smart triggered due to Write TA Factor

0x5D

0x02

Smart triggered due to Write Err Factor

0x5D

0x5B

Smart triggered due to spin retry

0x5D

0xFF

Smart test tripped

0x80

0x10

Block Slow PLL Error: recovered.

0x80

0x11

Split Slow PLL Error: recovered.

0x80

0x12

Block state machine disabled: recovered

0x82

0x20

Spoke-to-spoke time error: recovered

Sense

Key

Sense

Code

Sense

Qualifier

Meaning

Advertising