6-6

Maxtor Atlas 10K V

6.12

DIAGNOSTICS

The drive has extensive diagnostic capabilities, including those described below:
power-on self-test, periodic self-adjustments, and host diagnostics. Maxtor uses self-
diagnostic tests and sense data tracking to manage drive errors, in addition to logical
block address (LBA) revectoring.

6.12.1

Power On Self Test (POST)

The disk drive performs a self-diagnostic test immediately at power up. Both the Fault
LED and a Busy LED briefly illuminate during spin-up as a lamp test.

If the drive passes the self-tests (and the spin-up jumper is installed), it spins up and
performs further diagnostics on the Head Disk Assembly (HDA). The drive indicates
“not ready” until the HDA tests are completed successfully.

The drive diagnostics test the following:

• RAM and ROM chips

• Buffer memory

• Gate array chips

• Read/write encoding circuits

• Basic servo functions

After a SELECTION TIME following power-on, the disk drive is able to respond
with appropriate status and sense data to the TEST UNIT READY, INQUIRY, and
REQUEST SENSE commands.

6.12.2

Periodic Self-Adjustments

During normal drive operation, certain periodic functions occur automatically so the
drive can verify and maintain the integrity of its operations and optimize performance.
The operations performed include those listed below.

• Move/Switch idle heads

• Adaptive seek profile calibration

• ROM checksum

Such periodic functions can make the drive appear to be active when no commands
are outstanding, because the drive appears to be seeking. Periodic calibrations occur
only after the drive has been inactive for 30 seconds.

Note:

If a media access command is received during a calibration, the drive
aborts the calibration process and acts on the command.

If desired, calibrations can be suspended to reduce drive overhead by setting the
Manual Calibration bit in the (Vendor) Special Function Control page. If this is done,
manual calibrations can still be initiated by performing a REZERO UNIT command.