FORMAT UNIT Command Descriptor Block-Data Format

Table 5-12

FORMAT UNIT Command-Field Descriptions

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (04h)

1

Reserved

Fmt Data

Cmp

List

Defect List Format

2

Vendor-Specific

3 - 4

Interleave

5

Control

Field

Description

FmtData

Format Data. When the Format Data value is 1, it indicates that a data-out buffer transfer

occurs as part of the command execution. The FORMAT UNIT Parameter list (consist-

ing of a Defect List Header and, optionally, a number of Block Format Defect Descrip-

tors) is passed to the device during this phase.

When the Format Data value is 0, the data-out buffer transfer does not occur.

CmpLst

Complete List. When the Complete List value is 1, the drive deletes its current Grown

Defect List and starts a new one, containing the Logical Block Numbers listed in the de-

fect list supplied by the initiator during this format operation are added to the list, cre-

ating a new Grown Defect List.

When the Complete List value is 0, the drive adds initiator-supplied and newly found

defective Logical Block Numbers to the existing Grown Defective List.

Defect List Format

The Defect List Format value specifies the defect descriptor passed by the initiator to

the drive when the Format Data value is 1. Acceptable values are:

000b (Block [or Sector] Format)

100b (Index Format)

101b (Physical Sector Format)

Vendor-Specific

Not supported. Must be 0.

Interleave

Not supported. Ignored by the drive.