Environmental assumptions, General assumptions, General notes – Intel NetStructure MPCBL0001 User Manual

Page 108: Power consumption, 61 total measured power, 2 power consumption

Advertising
background image

108

Technical Product Specification

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

6.3.1.1

Environmental Assumptions

Failure rates are based on a 40

°

C ambient temperature.

Applied component stress levels are 50 percent (voltage, current, and/or power).

Ground, fixed, controlled environment with an environmental adjustment factor equal to 1.0.

6.3.1.2

General Assumptions

Component failure rates are constant.

Board-to-system interconnects included within estimates.

Non-electrical components (screws, mechanical latches, labels, covers, etc.) are not included
within estimations.

Printed circuit board is considered to have a 0 FIT rate.

6.3.1.3

General Notes

Method I, Case I = Based on parts count. Equipment failure is estimated by totaling device
failures rates and quantities used.

Quality Level II = Devices purchased to specifications, qualified devices, vendor lot-to-lot
controls for AQLs and DPMs.

Where available, direct component supplier predictions or actual FIT rates have been used.

The SBC MTBF does not include addition of the 2.5” HDD. The product MTBF could be
significantly impacted by adding a HDD. Please contact the HDD manufacturer for specific
component and relevant operational MTBF information.

6.3.2

Power Consumption

The power consumed by the Intel NetStructure

®

MPCBL0001 High Performance Single Board

Computer SBC is dependent on the type and speed of processors used and the amount of memory
installed.

Table 61, “Total Measured Power” on page 108

is based on the use of two Low Voltage

Intel

®

Xeon™ processors. Typical values were obtained by running the Windows* 2000*-based

application “Drive Reaper” against networked shared drives. “Max” values were obtained by
running Intel's DOS* based “Maxpower” utility, version 6.0.

Note:

A TriEMS card was installed for all power management tests. The TriEMS dissipates 550 mW
typical.

Note:

A TriEMS card was installed for all power management tests. The TriEMS dissipates 550 mW
typical. The power level that was sent to the shelf manager at M3 state is 152W. 10W margin from
the maximum power was an allowance for different model of PMC and DIMMs module.

Table 61.

Total Measured Power

Memory

Dual 2.0 GHz (400 Mhz FSB)

8GByte (Four 2-GByte DIMMs)

Typical power = 127 W
Max power = 142 W

Advertising