Sel events supported by the mpcbl0001 sbc – Intel NetStructure MPCBL0001 User Manual

Page 33

Advertising
background image

Technical Product Specification

33

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

Table 3.

SEL Events Supported by the MPCBL0001 SBC (Sheet 1 of 4)

Sensor

Type

Sensor

Type Code

Sensor-Specific

Offset (Event

Data 1, Bit 0-3)

Event

Remarks

Reserved

00h

-

Reserved

-

Temperature 01h

-

Temperature

Threshold exceeded for upper critical, upper non-
critical, lower critical and lower non-critical
thresholds. Refer to

Table 4, “Sensor Thresholds for

IPMC Firmware 1.0” on page 37

for sensor

thresholds data.

Voltage

02h

-

Voltage

Voltage exceeded upper critical, upper non-critical,
lower critical and lower non-critical thresholds. Refer
to

Table 4

for sensor thresholds data.

Processor

07h

00h

IERR

Processor IERR has occurred.

01h

Thermal Trip

Processor thermal trip has occurred.

04h

FRB3/Processor Startup/
Initialization Failure
(CPU did not start)

An FRB3 Timer (30 seconds) was implemented to
detect the failure of the CPUs from booting.
Event data 3 = Last Post 80 code byte

05h

Configuration Error

CPU 0 and CPU 1 are not present.

07h

Processor Presence
Detected

1

09h

Terminator Presence
Detected

1

Power Unit

01h

00h

Power Off/Power On

Normal power off indication. Offset 0 is just a status
indicating that the payload power is off. It does not
generate an event when it is set. (For internal use).

05h

Soft Power Control
Failure (unit did not
respond to request to
turn on)

The Power Unit sensor is used to detect when the
Payload power does not come up when the board is
told to power on.
When the board enters M4 state, the IPMC asserts a
Power Enable line to cause the Payload to power up.
The IPMC then waits for another line that indicates
that the power has come up successfully. If that line
does not assert within 2 seconds, then offset 05h is
asserted on the Power Unit sensor, which generates
an event to notify the Shelf Manager of the failure.

Memory

0Ch

00h

Correctable ECC

Event data 3 = DIMM pair number
00 refers to J8/J9
01 refers to J10/J11

01h

Uncorrectable ECC

Event data 3 = DIMM pair number
00 refers to J8/J9
01 refers to J10/J11

NOTE:

1. These sensor offsets do not generate events, but they are valid offsets when reading the sensor values.
2. Watchdog sensor refers to WDT#1 per

Section 3.13.1

.