Temperature and Voltage Sensors

Temperature and voltage readings are monitored by ADM1026. They are critical sensors that
ensure the MPCBL0001 is operating at its predefined threshold limits. The sensors are categorized
as follows:

Lower Non-Critical

Lower Critical

Upper Non-Critical

Upper Critical

If the lower critical or upper critical threshold is exceeded, it raises a major alarm. If the lower non-
critical or upper non-critical threshold is exceeded, it raises a minor alarm.

Only critical thresholds which are exceeded turn the Health LED solid red. However, for any
events above, IPMC forwards the events to the shelf manager to log it into shelf manager’s SEL.

FRU Hot
Swap

F0h

00h

M0 – FRU not installed

Refer to PICMG 3.0 Specifications (Table 3-14)

01h

M1 – FRU inactive

02h

M2 – FRU activation
request

03h

M3 - FRU activation in
progress

04h

M4 - FRU active

05h

M5 - FRU deactivation
request

06h

M6 - FRU deactivation in
progress

07h

M7 - Communication lost

IPMB Link
Sensor

F1h

00h

IPMB A & B disabled

Refer to PICMG 3.0 Specifications (Table 3-46)

01h

IPBM A enabled
IPMB B disabled

02h

IPMB A disabled
IPMB B disabled

03h

IPMB A & B enabled

Table 3.

SEL Events Supported by the MPCBL0001 SBC (Sheet 4 of 4)

Sensor

Type

Sensor

Type Code

Sensor-Specific

Offset (Event

Data 1, Bit 0-3)

Event

Remarks

NOTE:

1. These sensor offsets do not generate events, but they are valid offsets when reading the sensor values.
2. Watchdog sensor refers to WDT#1 per

Section 3.13.1

.