3.9

Hot-Swap Process

The MPCBL0001 SBC has the ability to be hot-swapped in and out of a chassis. The onboard
IPMC manages the SBC’s power-up and power-down transitions. The list below, along with

Figure 6

, illustrates this process.

1. Ejector latch is opened. HOT_SWAP_PB# assertion. IPMC firmware detects the assertion of

this signal.

2. IPMC sends "Deactivation Request" message to CMM. M state moves from M4-> M5.

3. Board moves from M5 -> M6 if the CMM grants the request.

4. The IPMC's ACPI timer (3 minutes) starts if an ACPI-enable OS is loaded. Otherwise, it goes

to Step 7 below. The IPMC asserts 20 ms pulse on SMC_PWRBTN#.

5. The Power Button Status register (PWRBTN_STS) is set. It then asserts SCI/SMI# to the OS.

If ACPI OS is enabled, SCI interrupt handler on the OS is called. Interrupt handler clears
PWRBTN_STS bit. OS starts to perform a graceful shutdown.

6. ICH3 detects "LOW" on the ICH3_PWRBTN#. Asserts ICH3_SLP_S3# and ICH3_SLP_S5#

to IPMC. Upon detection of ICH3_SLP_S5# and ICH3_SLP_S3#, board transitions to Step 7
below. If ICH3 doesn't assert the signals, the board will transition to Step 7 below upon the
ACPI timer expiration.

7. The firmware deasserts payload power and sets the IPMI locked bit before it transitions from

M6 to M1 state.

Note:

If the upper-level software moves the IPMC to M6, the same procedure is followed, starting with
Step 4.

Figure 6.

Hot-Swap Process

ACPI-OS

IPMC

CMM

ICH3

1

4

5

6

2

3

7