138

Technical Product Specification

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

Error Messages

9

9.1

BIOS Error Messages

The following table lists the error messages.

Note:

If user enabled "Wait for F1 Error" under BIOS setup screen and any of the above error message
was observed, the BIOS will wait for user input before proceeding with the boot up except:

1. CMOS Checksum BAD

Table 89.

BIOS Error Messages

Error Message

Explanation of Error Message

Timer Error

This timer is based on 8254 resides in ICH-3. Error message indicates an error while
programming the count register of the timer. This may indicate a problem with the timer in
ICH-3

CMOS Battery
Low

BIOS will report this error message when status bit (RTC_REGD.Bit7) in ICH3 is low. This
bit is hardwired to RTC power, so it will be low when the voltage in SuperCAP is low.

CMOS Settings
Wrong

BIOS will load default value after it detects CMOS corruption. Error message is triggered if
BIOS fails to load the default value to CMOS.

CMOS
Checksum Bad

CMOS contents failed the checksum check. Error message indicates that the CMOS data
has been changed by a program other than the BIOS or the CMOS is not retaining it's data
due to hardware malfunction

RAM R/W test
failed

Error message indicates BIOS fail to read/write to memory content during RAM R/W test.
RAM R/W test is executed during POST.

CMOS Date/
Time Not Set

Error message indicates BIOS has detected an invalid value in date & time register. (e.g.:
Invalid date = 50h or invalid month = 13h.

Clear CMOS
Jumper
installed

Error message indicates that Jumper J16-3 to 5 is set

Clear Password
Jumper
installed

Error message indicates that Jumper J16-1 to 3 is set

MFG Jumper
installed

Error message indicates that Jumper J16-9 to 10 is set. (Jumper is used only in
manufacturing test)

BMC is in
Update Mode

Error message indicates that Jumper J16-2 to 4 is set.

BMC does not
respond to
BIOS IPMI
command

Error message appears when BIOS issue an IPMI command to IPMC, but IPMC is not
responsive to the command and does not return successful completion code to BIOS.

System Event
Log is Full

Error message indicates the System Event Log storage is full.

Refresh timer
test failed

This timer is a counter based on 82C54 which provides memory refresh request signal
periodically. Memory content need to be refreshed to compensate for the gradual leakage
of charge from the capacitors which stores the data.

KBC BAT Test
failed

Error message indicates that Keyboard controller BAT test has failed.