Maintenance 12, 1 supervision, 2 diagnostics – Intel NetStructure MPCBL0001 User Manual

Page 162: Maintenance 12.1 supervision 12.2 diagnostics, 1 in-target probe (itp), 105 hardware monitoring components, Chapter 12, “maintenance, Maintenance

Advertising
background image

162

Technical Product Specification

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

Maintenance

12

12.1

Supervision

There are four main components that perform hardware monitoring of voltages and timers. They
are listed in the table below.

12.2

Diagnostics

12.2.1

In-Target Probe (ITP)

The ITP connector allows connection of a tool that helps you observe and control the step-by-step
execution of your program for debugging hardware and software. Debugging includes finding a
hardware or software error and identifying the location and cause of the error so it can be corrected.

Intel continually looks for ways to maximize the development and delivery of mission-critical tools
to our internal validation teams and strategic OEM customers. As a result, Intel has put together a
third-party vendor program team which works with third-party vendors to develop and deliver
specific tools formerly supplied by Intel to internal and external customers.

Intel recommends visiting any of the Website URLs below, and selecting a vendor of your choice
to provide in-circuit emulation hardware and software.

American Arium* currently develops in-circuit emulation and run control tools for Intel
processors for use by Intel BIOS and driver teams, Intel manufacturing, and OEM customers.

http://www.arium.com/

Agilent Technologies* currently develops logic analyzer and probing tools for Intel processors
for use by Intel validation teams (chip, system, platform) and OEM customers.

http://we.home.agilent.com

Tektronix* currently develops logic analyzer and probing tools for Intel processors for use by
Intel validation teams (chip, system, platform) and OEM customers.

http://www.tek.com/Measurement/logic_analyzers/index.html

Table 105.

Hardware Monitoring Components

Component

Function

Monitors

Intelligent Platform Management
Controller

WDT #1

Commands from the BIOS. If the timer expires
(times out), causes a soft or hard reset.

Heceta-5 (ADM1026)

Analog-to-Digital
converter

Voltages: +1.2 V, +1.5 V, +1.8 V, +3.3 VSB, +5 VSB,
VCPU, VTTDDR, +2.5 V, +12 V, -12 V, +5 V,
SuperCap (VBAT), IPMB_V, +1.8 VSB.

ICH3 (82801CA I/O Controller Hub 3) WDT #3

The first attempt to fetch an instruction after a power
failure.

PLD (2064VE)

WDT #2

Strobes by IPMC firmware. If it expires, it isolates
MPCBL0001 from the backplane IPMB buses and
resets the IPMC.

Advertising