Get hw fibre channel port selection, Set control state, 4 get hw fibre channel port selection – Intel NetStructure MPCBL0001 User Manual

Page 50: 5 set control state

Advertising
background image

50

Technical Product Specification

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

3.7.4

Get HW Fibre Channel Port Selection

This command returns the current Fibre Channel port routing selection as set in the hardware. The
command is available over KCS and IPMB interface SetFiberChannelPortSelection.

3.7.5

Set Control State

This command sets the state of a control pin and overrides the control pin’s auto state. Refer to

Table 20

on

page 52

for control number information.

Table 15.

Get Fibre Channel Port Selection

7

6

5

4

3

2

1

0

NetFn/LUN

NetFn = 3Ah (OEM Request)

RsLUN

Command

Cmd = 03h

Byte 1

Intel IANA number (LSB) = 57h

Byte 2

Intel IANA number = 01h

Byte 3

Intel IANA number (MSB) = 00h

Byte 1

Completion code

Byte 2

Intel IANA number (LSB) = 57h

Byte 3

Intel IANA number = 01h

Byte 4

Intel IANA number (MSB) = 00h

Byte 5

Fibre Channel 1 setting, 0=disabled, 1= Front panel, 2= Backplane, 3= reserved.

Byte 6

Fibre Channel 2setting, 0=disabled, 1= Front panel, 2= Backplane, 3= reserved.

Table 16.

Get HW Fibre Channel Port Selection

7

6

5

4

3

2

1

0

NetFn/LUN

NetFn = 3Ah (OEM Request)

RsLUN

Command

Cmd = 04h

Byte 1

Intel IANA number (LSB) = 57h

Byte 2

Intel IANA number = 01h

Byte 3

Intel IANA number (MSB) = 00h

Byte 1

Completion code

Byte 2

Intel IANA number (LSB) = 57h

Byte 3

Intel IANA number = 01h

Byte 4

Intel IANA number (MSB) = 00h

Byte 5

Fibre Channel 1 Settings, 1 = Front Panel, 2 = Backplane

Byte 6

Fibre Channel 2 Settings, 1 = Front Panel, 2 = Backplane