Technical Product Specification

37

Order #273817

Intel NetStructure

®

MPCBL0001 High Performance Single Board Computer

Contents

Table 4.

Sensor Thresholds for IPMC Firmware 1.0

Sensor Name

Sensor

Number

System Event

Log, reported

via CLI, SNMP,

RPC, RMCP

Normal

Value

LNR

LC

LNC

UNC

UC

UNR

+1.5 V

1Dh

Yes

+1.5 V

TBD

1.43

1.45

1.55

1.57

+2.5 V

17h

Yes

+2.5 V

TBD

2.3

2.36

2.625

2.7

+1.8 V

16h

Yes

+1.8 V

TBD

1.71

1.746

1.854

1.89

VTT DDR
(+1.25 V)

15h

Yes

+1.25 V

TBD

1.185

1.20

1.3

1.315

+1.2 V

14h

Yes

+1.2 V

TBD

1.14

1.176

1.224

1.26

+5 V

19h

Yes

+5 V

TBD

4.7

4.85

5.25

5.275

-12 V

1Bh

Yes

-12 V

TBD

-13.2

-12.6

-11.4

-10.8

+12 V

1Ah

Yes

+12 V

TBD

10.8

11.4

12.6

13.2

CPU Core
Voltage

1Ch

Yes

+1.3 V

TBD

1.24

1.26

1.345

1.36

+3.3 V

18h

Yes

+3.3 V

TBD

3.102

3.201

3.465

3.482

+1.8 VSB

12h

Yes

+1.8 V

TBD

1.71

1.73

1.836

1.89

+3.3 VSB

10h

Yes

+3.3V

TBD

3.102

3.201

3.465

3.482

+5 VSB

11h

Yes

+5 V

TBD

4.09

4.19

5.25

5.275

VBAT

13h

Yes

+3 V

TBD

2.0

2.4

3.4

3.6

Board
Temperature

30h

Yes

30

TBD

-5

5

60

70

CPU 0
Temperature

37h

Yes

40

TBD

5

10

76

81

CPU 1
Temperature

38h

Yes

40

TBD

5

10

76

81

NOTE:

The following terms apply:

LNR: Lower Non-Recoverable
LC: Lower Critical
LNC: Lower Non-Critical
UNC: Upper Non-Critical
UC: Upper Critical
UNR: Upper Non-critical

Advertising