SECTION 5

"

Software Download

5-30

6710 Access Point User’s Guide

"

You have established a connection between a PC and

the access point’s DIAG port, and have accessed the

ROM command monitor.

"

An old version of FLASH is in segment 1.

"

The new version of FLASH is going into segment 1.

"

Segment 2 is the active boot segment.

1. When the access point has entered the ROM command

monitor, type the following commands to upgrade the

unit.

Command

Description

ap>pwd

Enter the password menu.

Enter the password.

The default password is

CR52401OWL (must be upper-

case).

passwd>fe 1

Erase FLASH segment 1.

passwd>x

Exit the password menu.

ap>fx 1

Download the new FLASH file into

segment 1.

passwd>fb 1

Change the boot segment number

from 2 (in this example, the active

boot segment) to 1.

ap>fr

Run the new FLASH boot file by

restarting the access point.

2. After the access point reboots and is running in

FLASH mode, use the Fd command to display the file

directory and verify that the new version of FLASH is

in segment 1.

3. Ensure that this access point has a valid IP address.

Change the address if necessary and remember what

it is. You need the IP address to configure TFTP

clients in other access points.