SECTION 6

"

Indicator Lights

6710 Access Point User’s Guide 6-3

STATUS

The STATUS (left) light indicates the access point’s

operating status. When the light is OFF, the access point is

operating normally. When the light is ON, it is in error

mode.

" NOTE:

In certain cases the following text refers to the indicator lights by

number. Lights are numbered from left to right. Light 1 is labeled

LINK and Light 8 is labeled NIC2.

The access point enters error mode when it detects a

malfunction during the power-on self tests or when certain

hardware malfunctions occur during normal operation.

When the STATUS light is ON to indicate the error mode,

indicator lights 4 through 8 (the STATUS MODE light and

the NETWORK and PCMCIA light pairs) display a binary

error status code between 1 and 31. This code indicates the

specific condition causing the error status as shown in

Table 6-2. Descriptions of errors are on page 6-4.

Table 6-2

Error Mode Status Codes

Status Mode R-LINK W-LINK NIC1 NIC2 Error Status
ON

OFF

OFF

OFF

OFF

ON

Hardware error 1.

ON

OFF

OFF

OFF

ON

OFF

Hardware error 2.

ON

OFF

OFF

OFF

ON

ON

Hardware error 3.

ON

OFF

OFF

ON

OFF

OFF

Internal serial loop-

back test failed.

ON

OFF

OFF

ON

OFF

ON

Internal MACE AUI

loopback test failed.

ON

OFF

OFF

ON

ON

OFF

Internal 10BASE-T

loopback test failed.

ON

OFF

OFF

ON

ON

ON

Timer test failed.