7 rs485 setup – Speco Technologies DVR-16TS User Manual

Page 79

Advertising
background image

User’s Manual

DVR-4TN/8TN/16TN/16TS/16TT Series

SPECO TECHNOLOGIES 01/08

78

ezDDNS

ezDDNS

enables the users to register for the host name automatically. Press

ENTER and select YES. The following screen will be displayed:

ezDDNS Submit/update ok!

Host name is XXXX_XXXXXX

Press any key to return

NOTE:

The DVR must be connected to the *Real IP address, or be

assigned a specific port using **Port Forwarding technique.

*

A "Real IP" is the IP address that is assigned to you by your ISP.

**A "Virtual IP" is the IP address assigned either manually or through
DHCP. When the user is assigned a Virtual IP, the user must use Port

Forwarding

technique to assign a specific port to the DVR.

5.1.7

RS485 Setup

This menu allows the user to setup the parameters of the unit’s RS-485
communications port. From the Main menu, select <RS485 Setup> and press
ENTER. The following menu is displayed.

RS485 Setup

1. Unit ID
2. Baud Rate
3. Bits
4. Stop
5. Parity

224

9600

8
1

None

5.1.7.1

Unit ID

This item is used to change the RS-485 ID address of the unit. The ID is with
the range of <1> to <255>. The default is <224>.

5.1.7.2

Baud Rate

The Baud rate options for association with the protocol are <2400>, <4800>,
<9600>, <19200>, <38400> and <57600>. The default is <9600> baud.

5.1.7.3

Bits

The user can specify the bits in a word that are associated with this protocol.
The available options are <6>, <7> and <8> bits. The default is <8> bits.