5 covert, 6 termination, 7 brightness – Speco Technologies DVR-16TS User Manual

Page 85

Advertising
background image

User’s Manual

DVR-4TN/8TN/16TN/16TS/16TT Series

SPECO TECHNOLOGIES 01/08

84

• Use Direction keys to position the cursor in the title entry field above the

virtual keyboard.

• Use Direction keys to move the cursor through the lists of characters to the

one you need. Press ENTER to select a character. Continue until the
name is established. Each title can contain up to 11 characters in it.

• After the title entry is finished, move the cursor to <OK> and press ENTER;

otherwise, either press ESC, or move the cursor to <Cancel> and press
ENTER to abort.

5.3.5

Covert

This function allows the user to choose a specific camera to be covert while
the unit is continuing to record video. Choosing <YES> means to covert the
selected camera; and <NO> the selected camera remains non-covert. The
default setting is <NO>.

To set a camera to be covert, follow these steps:

• Select the channel that you want to be covert from the <Channel Select>

item.

• After selecting the channel, move the cursor to <Covert> item and select

<YES>.

5.3.6

Termination

This item is used to enable / disable the 75-termination resistor inside the
unit .that adjusts the image quality of each camera. <YES>= termination
resistor enabled (default), <NO> = termination resistor disabled.

NOTE:

If the camera loop-out connectors have not been used, the

termination resistor should be enabled for appropriate signal

termination.

5.3.7

Brightness

Move the cursor to this item and press ENTER to adjust the brightness of the
camera. Use UP / DOWN keys to adjust the numeric value. The range of
brightness values is <-128> to <127>. The default setting is <0>.