Configuring the Programmable Models

31007492

63

4. Start your Borland compiler development environment as described

in your compiler documentation.

5. Update the BM85 Project file BM85.PRJ to set the correct directory

paths for your Borland environment. For example, in the Borland

3.1 environment, you can use the following key sequence:

Key Sequence

Purpose

Alt–P

Project open

BM85.PRJ

Project name

Alt–O D

Option directories

(paths)

Update the paths for your INCLUDE and LIBRARY directories

6. If either of these parameters is true, continue with Step 7. If

neither is true, skip Step 7 and go to Step 8.

h Your SA85/SM85 interrupt is set to a vector other than 5C

h Your BM85 Modbus Plus node address is other than 4.

7. Update the BM85LOAD and MBPSTIM command lines in the BM85

project's TRANSFER menu to use the new parameters. In the

Borland 3.1 environment, you can use the following key sequence:

Key Sequence

Purpose

Alt–T

Transfer menu

Select command line

Select the BM85 DOWNLOAD or MBPLUS STIMULATE line

Alt–E

Edit

Alt–C

Command line

Enter parameters

Set the parameters as they are used in your application

Alt–M

Modify

Alt–K

OK

8. When you have updated your project file, close the project. In the

Borland 3.1 environment, you can use the following key sequence:

Key Sequence

Purpose

Alt–C

Project close