RECORD SET

2

English

109

[Settings] (‹ indicates default setting)

6

Turn the shuttle dial clockwise.

“FULL” flashes.

7

Turn the jog dial to select the “MAIN

MON. DISPLAY” setting and then turn

the shuttle dial clockwise.

The cursor moves to “ALARM PRIORITY”.

[Settings] (‹ indicates default setting)

*1 Multi screen display is laid out according to the settings on

P.132. Therefore, the image for the channel for which an
alarm was detected may not be displayed depending on
the settings when multi 9 screen display is selected.
Special care should be taken.

*2 Only for the DSR-5716P

8

Turn the shuttle dial clockwise.

“LAST” flashes.

9

Turn the jog dial to select the “ALARM

PRIORITY” setting and then turn the

shuttle dial clockwise.

The cursor moves to “MON.2 DISPLAY”.

[Settings] (‹ indicates default setting)

Setting

Description

‹

OFF

Even if a new alarm is received on the same
channel during alarm recording, the duration is not
extended.

ON

If a new alarm is received on the same channel
during alarm recording, the duration is extended
and both alarms are treated as one.
(Example: Even if alarms A and C are received in
succession, or alarms A, B and C are received in
order as shown below, alarm recordings A and C
are treated as one, provided that alarm C occurs
while alarm recording is in progress for alarm A.)

Alarm

Alarm

Alarm recording A

Example:

Alarm

Alarm recording C

Alarm recording B

CH 1

CH 2

<ALARM OPERATION SET>

ALARM RETRIGGER : ON

MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC

<ALARM OPERATION SET>

ALARM RETRIGGER : ON

MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC

Setting

Description

‹

FULL

When an alarm is detected, the main monitor
displays in full screen format the video on the
channel containing the alarm.

9

*1

When an alarm is detected, the main monitor
displays multi 9 screens.

16

*2

When an alarm is detected, the main monitor
displays multi 16 screens.

NC

The display on the main monitor does not change
when an alarm is detected.

Setting

Description

‹

LAST

When a number of alarms occur, the most
recent alarm video is given priority and is
displayed.

FIRST

When a number of alarms occur, only the
video for the first alarm is displayed.
However, if the duration for the first alarm
expires, video for the next alarm is
displayed.

SWITCH

When a number of alarms occur, the
display switches between the video from
the corresponding cameras, showing each
for one second.

<ALARM OPERATION SET>

ALARM RETRIGGER : ON

MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC

<ALARM OPERATION SET>

ALARM RETRIGGER : ON

MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC