General set 3, Setting rs-485 – Sanyo DSR-5716P User Manual

Page 121

Advertising
background image

120

English

GENERAL SET

3

INTRODUCTION

SE
TTINGS

NE
T

W

O

R

K

CO
NT
RO
L

NETW

ORK

O

P

E

RATION

NE
T

W

ORK

S

E

TTINGS

OTHE

R

OPE

RATION

Settings are required when RS-485 terminal (A and B) is
connected with a system controller or other devices.

1

Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is
displayed.

2

Turn the jog dial to select “3.GENERAL

SET” and then turn the shuttle dial

clockwise.

The <GENERAL SET> screen is displayed.

3

Turn the jog dial to select “4.RS-485

SET” and then turn the shuttle dial

clockwise.

The <RS-485 SET> screen is displayed.

4

Turn the shuttle dial clockwise.

“19200” flashes for “DATA SPEED”.

5

Turn the jog dial to select the “DATA

SPEED” setting and then turn the

shuttle dial clockwise.

The cursor moves to “STATUS INFO”.

[Settings] (‹ indicates default setting)

6

Turn the shuttle dial clockwise.

“OFF” flashes for “STATUS INFO”.

7

Turn the jog dial to select “STATUS

INFO” and then turn the shuttle dial

clockwise.

The cursor moves to “ALARM INFO”.

[Settings] (‹ indicates default setting)

Setting RS-485

MENU

<RS-485 SET>

DATA SPEED : 19200

STATUS INFO : OFF

ALARM INFO : OFF

ADDRESS : 001

<RS-485 SET>

DATA SPEED : 19200

STATUS INFO : OFF

ALARM INFO : OFF

ADDRESS : 001

Setting

Description

2400, 4800, 9600, ‹19200

Sets the data speed.

Setting

Description

ON

Status information is transmitted.

‹

OFF

Status information is not transmitted.

<RS-485 SET>

DATA SPEED : 19200

STATUS INFO : OFF

ALARM INFO : OFF

ADDRESS : 001

<RS-485 SET>

DATA SPEED : 19200

STATUS INFO : OFF

ALARM INFO : OFF

ADDRESS : 001

<RS-485 SET>

DATA SPEED : 19200

STATUS INFO : OFF

ALARM INFO : OFF

ADDRESS : 001