F117 – Factory Configuration

Note: The standard XLi IEEE 1588 clock includes the TIET option as a standard feature. The other optional
software features, NTP, FREQ MEAS, and PPO, are unavailable for the standard XLi IEEE 1588 clock.

Use function F117 to display the XLi factory Serial Number and the availability of optional software
features. Send the string:

F117<CR>

XLi responds:

F117<S>SN<S><SERIAL#><CR><LF>

NTP <STATE><CR><LF>

FREQ MEAS <STATE><CR><LF>

TIET <STATE><CR><LF>

PPO <STATE><CR><LF>

where:

For example, enter:

F117<CR>

XLi responds:

F117 SN 31234<CR><LF>

NTP ENABLE<CR><LF>

FREQ MEAS ENABLE<CR><LF>

TIET ENABLE<CR><LF>

PPO ENABLE<CR><LF>

F

= ASCII

character

F.

117

= function

number.

<S>

= ASCII space character one or more.

NTP

= NTP

option

FREQ MEAS

= FREQ

MEAS

option

TIET

= TIET

option

PPO

= PPO

option

<CR>

= carriage

return.

<STATE>

= ENABLE

or

DISABLE

<LF>

= line

feed.

Advertising