Symmetricom XLi IEEE 1588 User Manual

Page 178

Advertising
background image

170

XLi IEEE 1588 Clock

997-01510-03, Rev. C, 12/12/2006

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

1

maskFirstTimeLock OBJECT-TYPE

SYNTAX FaultMaskType

MAX-ACCESS read-write

STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the locking status of the

clock since power on changes."

::= { systemFaultConfigMasks 11 }

maskTimeError OBJECT-TYPE

SYNTAX FaultMaskType

MAX-ACCESS read-write

STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the time error threshold

is reached."

::= { systemFaultConfigMasks 12 }

maskTimeout OBJECT-TYPE

SYNTAX FaultMaskType

MAX-ACCESS read-write

STATUS current

DESCRIPTION

"If enabled, an alarm can be triggered when the timeout threshold is

reached."

::= { systemFaultConfigMasks 13 }

maskNtp OBJECT-TYPE

SYNTAX FaultMaskType

MAX-ACCESS read-write

STATUS current

DESCRIPTION

"If enabled, an alarm will be triggered when NTP is in alarm."

::= { systemFaultConfigMasks 14 }

faultPllSynthesizerOBJECT-TYPE

SYNTAX Boolean

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"TRUE, if a PLL synthesizer fault occurred since the fault

latch was cleared."

::= { systemFaultHistory 1 }

faultLpnPllOBJECT-TYPE

SYNTAX Boolean

MAX-ACCESS read-only

STATUS current

DESCRIPTION

"TRUE, if a LPN PLL fault occurred since the fault

latch was cleared."

::= { systemFaultHistory 2 }

Advertising