To see the states the Alarm Latches for all of the indicators, enter:

F73<S>LATCH<CR>

XLi replies:

F73<S>LATCH<SEP><123><CR><LF>

To clear the Alarm Latches, enter:

F73<S>CLEAR<SEP>ALARM<SEP>LATCH<CR>

XLi replies:

OK

The command line uses a ‘mask’ to enable or disable each indicator’s alarm. To see which indicators are
Alarm Enabled, enter:

F73<S>MASK<CR>

XLi replies:

F73<S>MASK<SEP>M<12346789ABCDE><CR><LF>

where:

'U' Time error Fault

D

= '-' Timeout OK

'T' Timeout Fault

E

= '-' NTP OK

'N' NTP Fault

‘E’

= enabled

‘D’

= Disabled