F100 - network port configuration & xli firmware, F100 – network port configuration & xli firmware – Symmetricom XLi IEEE 1588 User Manual

Page 88

Advertising
background image

80

XLi IEEE 1588 Clock

997-01510-03, Rev. C, 12/12/2006

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

1

F100 – Network Port Configuration & XLi Firmware

F100 provides two groups of commands:

Group 1, available through the keypad/display and the command line, provides access to

network port settings and hardware/Firmware status information.

Group 2, available through the command line only, provides commands for changing system

firmware, changing SNMP parameters, changing the user name/password, resetting the unit,
and pinging other network devices.

Warning: The F100 commands have the capacity to remove the XLi from the network and disable the
XLi’s system firmware. Use judiciously.

Reboot Warning: Saving changes to any F100 parameter using the keypad/display will reboot the XLi.
Some of the F100 command line commands also reboot the XLi. These are identified in the following
documentation.

Group 1

You can use both the keypad/display and the command line interface to access the following
parameters:

Ethernet address: XLi contains a unique Ethernet or Media Access Control (MAC) address

comprised of a unique number assigned to the manufacturer, and a unique number assigned to
the unit. This is factory set and cannot be changed.

IP Address: Sets a static Internet Protocol (IP) address for the unit.

Subnet Mask: Sets a valid subnet-mask used in IP addressing. Subnetting allows for the more

efficient allocation of network addresses and management of network traffic.

Default Gateway: The address of the router that handles packets addressed to IP devices

outside the local-area network.

10 100 BASE-T: The network port bandwidth setting, 10 Base-T or AUTO. (10 Base-T only for

earlier XLi hardware).

Remote Lockout: Enables or disables remote access through the XLi’s standard network port.

Enabling Remote Lockout limits users to the front-panel keypad or Serial I/O port.

Flash CRC: Status - Passed or failed.

RAM: Status - Passed or failed.

Serial: Status - Passed or failed.

Version Test: Status - Passed or failed