Partitioning Process

154 SL500 User’s Guide • July 2008

Revision: KA • 96116

Information in the SL Console partition workspace is committed to the library

controller database only through the Commit (Step 4) screen. The information is lost if

any one of the following occurs before you have committed your updates:

You actively log off the SL Console session.

The SL Console session times out or the connection to the library is lost.

You actively refresh the SL Console workspace from the current library controller

database. This is done through the Refresh button on the Summary (Step 2) and

Design (Step 3) screens.

Caution –

For the following reasons, it is recommended that you make the library

unavailable to other users before committing your partition workspace changes.

There is no real-time validation of partition boundaries against the library controller

database; therefore if you do not make the library unavailable and other users are

performing cartridge movements or library configuration changes, configuration

conflicts may arise. See

“Synchronizing the Display With the Controller Database” on

page 31

for details.

The library temporarily drops all connections to HSC or ACSLS hosts when partition

configurations changes are committed. The hosts will automatically reconnect, but

multiple error messages will be displayed, and cartridge management tasks in progress

may fail.