Library self-tests, Library self-tests 250 – Sun Microsystems StorageTek Modular Library System SL500 User Manual

Page 282

Advertising
background image

Library Self-Tests

250 SL500 User’s Guide • July 2008

Revision: KA • 96116

Library Self-Tests

The self-test diagnostic utility is intended to help diagnose basic problems with the

library. A self-test is typically run after the library is installed. It can be run whenever

necessary.

Note –

The library self-test routines are non-disruptive.

Library self-tests involve the following process:

1. Checks the communication path between the library controller, drives, and HandBot.

2. Performs get and put operations to check the health of the HandBot and CAPs. This

includes get and put operations from a reserved cell to a random empty:

Storage cell

CAP cell

Corner cell

3. Performs a full library audit.

4. Performs mounts and dismounts of diagnostic cartridges for all the drives installed

in the library.

Note –

The self-test will not start unless a diagnostic cartridge is found in the reserved

cells.

Note –

The self-test is repeated for each drive type if a compatible diagnostic cartridge

is found in the reserved cells. If a diagnostic cartridge is not found for a drive type, the

mount/dismount operation is skipped for the drive.