Partition Design and Commit Screens

96116 • Revision: KA

Chapter 6 Library Partitioning 223

Partitions—Commit (Step 4)—Confirm Apply

Sample Screen

Description

Displays a list of configuration errors in the current SL Console partition workspace.

This screen is a popup that appears when you click Apply on the

Partitions—Commit (Step 4)

screen.

After viewing the error messages, you can commit all data in the SL Console partition

workspace to the library controller database by clicking the Yes button.

Possible errors include:

A partition has orphaned cartridges. See

“Orphaned Cartridges in Partitioned

Libraries”

for details.

Library resources have been removed from a partition.

A host-partition connection does not have a partition assigned to LUN 0 (applies to

FC-SCSI connections only).

If any of these error conditions are present, the screen initially displays summary

warning messages. You can view detailed messages by clicking the Details button.

It is recommended that you resolve all errors before committing the data to the library

controller database.

Optionally, you can print the screen data or save it to a comma-separated file.