Table 1-6 – Sun Microsystems StorageTek Modular Library System SL500 User Manual

Page 45

Advertising
background image

Controls and Indicators

96116 • Revision: KA

Chapter 1 SL500 Introduction 13

Service Required
See

TABLE 1-6

for details.

Indicator

LED is normally not lit.

LED is lit when the library experiences a failure or is in a

non-ready state.

Open Door

Indicator

LED flashes amber when the Open Door button is pressed.

LED is solid amber when the robot is parked in the robotics

unit.

LED flashes during initialization and audit.

LED is not lit when the library is ready for customer use.

Button
When pressed:
1. Software allows the current job to complete. This could take a

while.

2. Software retracts the robot into the robotics unit so that it will

not be damaged when you open the door with the key.

Open CAP

Indicator

LED is amber when any CAP doors are open.

LED is not lit when all CAP doors are shut.

Button
Button is used to open all CAP doors in a rack.

TABLE 1-6 Keypad Service Required LED

Activity

Meaning

Action

Flashing

The redundant component failed.

The service representative might need to

replace the failed redundant component,

such as power supply, tape drive, or

fan.

Diagnostics are running.

Nothing, this is normal.

Diagnostics failed.

The service representative might need to

check the log_error file for the result

code and perform the appropriate

action.

Door is open.

Close and lock the door.

On solid

The non-redundant component failed.

This includes the last working

component of a redundant set of

components, such as tape drives.

The service representative might need to

check the log_error and
log_warning

files to determine which

component failed, and replace the failed

component.

The library has stopped operating.

The service representative might need to

check the log_error file for the result

code and perform the appropriate

action.

TABLE 1-5 Keypad Buttons and Indicators (Continued)

Buttons/Indicator

Description