Sun Microsystems StorageTek Modular Library System SL500 User Manual

Page 200

Advertising
background image

Partition Configuration Tasks

168 SL500 User’s Guide • July 2008

Revision: KA • 96116

Note –

This verification is performed on the current partition configuration in the

SL Console partition workspace only. It does not verify current partition boundaries

against the library controller database; therefore it cannot identify configuration

conflicts that may arise due to other users performing cartridge movements or library

configuration changes—through the command line interface, other SL Console sessions,

or host applications—at the same time you have made partition changes.

The Confirm Apply popup appears, indicating whether there are any orphaned

cartridges or other problems in the current partition configuration.

4. To display detailed warning messages explaining the reasons for any orphaned

cartridges, click Details.
You can use the Details button to toggle between the expanded and collapsed views of

the warning messages.

5. Optionally, in the expanded view of the warning messages you can do the following:

Click Print to print the detailed message data.

Click Save to save the detailed message data to a comma-separated file.

6. Proceed as follows:

Advertising