OPERATION

B-1

Read and understand this entire section before
operating your Idealarc CV-300.

SAFETY INSTRUCTIONS

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such

as output terminals or internal wiring.

• Insulate yourself from the work and

ground.

• Always wear dry insulating gloves.

____________________________________

____________________________________

____________________________________

____________________________________

Only qualified personnel should operate this equip-
ment. Observe all safety information throughout this
manual.

When using a CV-300 power source with wire feed-
ers, there will be a small spark if the electrode con-
tacts the work or ground within several seconds
after releasing the trigger.

When use with some wire feeders with the electri-
cal trigger interlock in the ON position, the arc
might restart if the electrode touches the work or
ground during these several seconds.

____________________________________

GENERAL DESCRIPTION

Product Description

The IDEALARC CV-300 is a constant voltage DC
power source designed for the GMAW process with
limited FCAW capability. It features an industrial rating
of 300 amps, 32 volts, at 100% duty cycle. It complies
with the requirements for a NEMA Class I (100) power
source. It is available from the factory in one model
only, with no options other than input voltage or fre-
quency.

No options are available other than input voltage.

The IDEALARC CV-300 includes the following fea-
tures:

Two inductance positions: operator can
choose the optimum output characteristics.

Solid State Output Contactor: no noise, no
moving parts to wear.

Digital Voltmeter/Ammeter is standard.

42 VAC, 10 amp auxiliary power available for
the wire feeder.

Circuit breaker protected.

115 VAC, 5 amp auxiliary power available for
the wire feeder; circuit breaker protected.

IDEALARC CV-300

WARNING

FUMES AND GASES
can be dangerous.

• Keep your head out of fumes.

• Use ventilation or exhaust to

remove fumes from breathing
zone.

ARC RAYS
can burn.

• Wear eye, ear and body

protection.

WELDING, CUTTING and
GOUGING SPARKS
can cause fire or explosion

• Keep flammable material away.

• Do not weld, cut or gouge on

containers that have held com-

bustibles.

CAUTION