THEORY OF OPERATION

E-1

IDEALARC CV-300

INPUT LINE VOLTAGE, LINE SWITCH
AND MAIN TRANSFORMER

The desired three phase input power is connected to
the CV 300 through an input line switch located on the
front of the machine. A reconnect panel allows the user
to configure the machine for the desired input voltage.
This AC input voltage is applied to the primary of the
main transformer.

The main transformer changes the high voltage, low
current input power to a low voltage, high current out-
put. The finishes or "neutrals" of the main secondary
coils are connected together and the three starts of the
secondary windings are connected to the rectifier
assembly. In addition the main transformer also has
several isolated auxiliary windings. The 115 VAC auxil-
iary winding supplies power to operate the cooling fan
and offers up to 5 amps to operate wire feeding equip-

ment. A separate 42 VAC winding is connected to the
14 pin amphenol to supply up to 10 amps for 42 VAC
wire feeders. The two isolated 12 VAC coils supply
power and gate firing timing information to the control
board.

Figure E.2 - Input Line Voltage, Line Switch and Main Transformer

POWER SUPPLY OPERATION

INPUT

LINE

SWITCH

MAIN

TRANSFORMER

RECONNECT

PANEL

FAN

MOTOR

OUTPUT

RECTIFIER

+

SHUNT

CHOKE

OUTPUT
TERMINALS

CONTROL BOARD

F

E

E

D

B

A

C

K

G
A
T
E
S

METER

OUTPUT

CONTROL

14 PIN

AMPHENOL

TRIGGER AND REMOTE

12VAC

12VAC

4
2
V
A
C

-

CAPACITORS

+

F

E

E

D

B

A

C

K

-

-

115VAC

NOTE: Unshaded areas of Block Logic

Diagram are the subject of discussion

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising