PROCEDURE FOR CLAMPING
1/4-28 BOLTS.
Note: This procedure can only be used
with 1/4-28 bolts.
Do not use bolts with any other type
thread or new SCR will be damaged.
Do not over tighten cap screws. The
leaf spring will apply the required clamp-
ing force to the SCR.
1.
Do not turn the nuts. While holding
nuts stationary, turn the cap screws
only with the following procedure.
2.
Tighten first cap screw 1/4 turn.
3.
Tighten second cap screw 1/2 turn.
4.
Tighten first cap screw 1/2 turn.
5.
Tighten second cap screw 1/2 turn.
6.
Tighten first cap screw 1/2 turn.
7.
Tighten second cap screw 1/4 turn.
8.
Assembly now has the proper
clamping force.
9.
CLAMPING PROCEDURE FOR
1/4-20 BOLTS.
Note: This procedure can only be used
with 1/4-20 bolts.
Do not use bolts with any other type
thread or new SCR will be damaged.
Do not over tighten cap screws. The
leaf spring will apply the required clamp-
ing force to the SCR.
1.
Do not turn the nuts. While holding
the nuts stationary, turn the cap
screws only with the following pro-
cedures.
2.
Tighten first cap screw 1/4 turn.
3
Tighten second cap screw 1/2 turn.
4.
Tighten the first cap screw 1/2 turn.
5.
Tighten the second cap screw 1/4
turn.
6.
Tighten the first cap screw 1/8 turn.
7.
Tighten the second cap screw 1/8
turn.
8.
Assembly now has the proper
clamping force.
9.
F-42
TROUBLESHOOTING & REPAIR
F-42
IDEALARC CV-300
SCR REMOVAL AND REPLACEMENT (CONTINUED)