F-4

TROUBLESHOOTING & REPAIR

F-4

IDEALARC CV-300

TROUBLESHOOTING GUIDE - Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The machine has low output and no
control. The fan runs and the dis-
play is lit.

1.

If the machine has normal out-
put in machine control, but not in
remote control, check the
remote switch (S4). Check the
wiring to the control board and
to the 14 pin amphenol.

2.

If the machine has low output in
machine control check the out-
put control (R2) and associated
leads.

3.

Check the feedback leads from
the shunt and the output termi-
nals to the control board. See
wiring diagram.

4.

Perform the

Main Transformer

Test.

5.

Perform the

Output Rectifier

Bridge Test.

6.

Check the latching resistor (R1)
and the associated leads. See
wiring diagram.

7.

Check for loose or faulty con-
nections at the output terminals
and the heavy current carrying
leads.

8.

The control board may be faulty.
Replace.

1.

Place the remote switch in
machine control. If normal out-
put is restored then the remote
control unit may be faulty.
Check or replace.

2.

If an error message is displayed
see

Explanation of Error

Messages.

3.

Make sure the three phase input
voltage matches the reconnect
panel configuration and that all
three phases are applied to the
machine.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-
383-2531 or 1-800-833-9353

CAUTION