F-23

TROUBLESHOOTING & REPAIR

F-23

IDEALARC CV-300

5ms

20V

0 Volts

CH1

This is a typical CV output voltage generat-
ed from a properly operating machine. Note
that each vertical division represents 20
volts and that each horizontal division rep-
resents 5 milliseconds in time.
The machine was loaded with a resistance
grid bank.

Note: Scope probes connected at machine
high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep . . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . .DC.

Trigger . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

MACHINE LOADED TO 300 AMPS AT 32 VDC

TYPICAL DC WELD OUTPUT - MACHINE LOADED