Abnormal open circuit weld voltage waveform, Troubleshooting & repair – Lincoln Electric IDEALARC CV-300 User Manual

Page 65

Advertising
background image

F-26

TROUBLESHOOTING & REPAIR

F-26

IDEALARC CV-300

5ms

20V

0 Volts

CH1

This is not the typical output voltage wave-
form. The output capacitors were discon-
nected to simulate a faulty capacitor bank.
Note the absence of “filtering” in the wave-
form. Note that each vertical division repre-
sents 20 volts and each horizontal division
represents 5 milliseconds in time.

Note: Scope probes connected at machine
high inductance output terminals.

Volts/Div . . . . . . . . . . . . . . . . .20 V/Div.

Horizontal Sweep . . . . . . . . . .5 ms/Div.

Coupling . . . . . . . . . . . . . . . . . . . . .DC.

Trigger . . . . . . . . . . . . . . . . . . .Internal.

SCOPE SETTINGS

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

NO LOAD - CAPACITOR BANK NOT FUNCTIONING