Troubleshooting & repair, Procedure, Capacitor bank removal and replacement (continued) – Lincoln Electric IDEALARC CV-300 User Manual

Page 70

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

F-31

TROUBLESHOOTING & REPAIR

F-31

IDEALARC CV-300

PROCEDURE

1.

Disconnect main AC input power to
the machine.

2.

Test that the capacitors are dis-
charged using a voltmeter.

a.

Polarity must be observed.

3.

Disconnect the following compo-
nents from the capacitor bank
assembly: See Figure F. 17.

4.

Remove the two screws holding the
capacitor mounting strap to the lift
bail assembly using a 5/16"
Nutdriver.

a.

Note placement of insulation.

5.

Carefully remove the capacitor bank
assembly.

CAPACITOR BANK REMOVAL AND REPLACEMENT (CONTINUED)

PART TO REMOVE

Diode D1 pigtail and lead #224A

Diode D2 pigtail

Diode D3 pigtail, output choke

lead, and leads #224 and #224B

Diode D5 pigtail

Diode D4 pigtail

Positive capacitor jumper strap

Positive capacitor output lead

LOCATION

Negative capacitor bank buss

Negative capacitor bank buss

Negative capacitor bank buss

Negative capacitor bank buss

Positive capacitor jumper strap

Positive capacitor buss

Positive capacitor buss

TYPE WRENCH

1/2" open end wrench

1/2" open end wrench

1/2" open end wrench

1/2" open end wrench

7/16" open end wrench

1/2" open end wrench

1/2" open end wrench