TROUBLESHOOTING & REPAIR

F-19

IDEALARC CV-300

TEST PROCEDURE

1.

Disconnect main AC input power to
the machine.

2.

Locate and remove the following
plugs:

See Figure F.11.

FIGURE F.11 - Molex plug locations.

3.

Locate resistor R1 and remove lead
#224. See wiring diagram.

4.

Disconnect the strap from the posi-
tive heat sink to the capacitor bank
using a 1/2" wrench. See Figure
F.12.

FIGURE F.12 - Procedure to discon-
nect the strap from the positive heat
sink to the capacitor bank.

5.

Disconnect the D5 diode pigtail from
the negative capacitor buss using a
1/2" wrench. See Figure F.13.

FIGURE F.13 - Procedure to discon-
nect the D5 diode pigtail from the
negative capacitor buss.

ACTIVE SCR RECTIFIER ASSEMBLY TEST (CONTINUED)

CONTROL

BOARD

SNUBBER

BOARD

PLUG #

J5
J1
J3

LOCATION

Snubber board

Control board

Control Board