LN-25 TO CV-300

1.

Turn the ON/OFF POWER SWITCH to OFF.

2.

Plug a K484 jumper plug into the CV-300 wire
feeder receptacle.

3.

Connect the work and electrode cables.

a.

Connect the positive output lead to the termi-
nal marked (+).

b.

Connect the negative output lead to either the
low inductance terminal marked ( ) or the high
inductance terminal marked ( ).

The output terminals are energized at all times
when the K484 is plugged in.

____________________________________

LN-742 TO CV-300

1.

Turn the ON/OFF POWER SWITCH to OFF.

2.

Connect the LN-742 control cable to the wire feed-
er receptacle on the CV-300.

3.

Connect the work and electrode cables.

a.

Connect the positive output lead to the termi-
nal marked (+).

b.

Connect the negative output lead to either the
low inductance terminal marked ( ) or the high
inductance terminal marked ( ).

CONNECTING REMOTE CONTROL (K857)
TO CV-300

1.

Turn the ON/OFF POWER SWITCH to OFF.

NOTE: The K864 Remote Control Adapter is required
to install the K857.

2.

Plug the K864 Remote Control Adapter into the
power source's 14-pin receptacle.

C-2

ACCESSORIES

C-2

3.

Plug the K857 Remote Control into the 6-pin
receptacle of the K864 adapter. If possible, tape
the Remote cable to the heavy output leads, so
they can protect the smaller Remote Control cable
from damage and abuse.

IDEALARC CV-300

WARNING