Troubleshooting, Section, Played, see – Lincoln Electric IDEALARC CV-300 User Manual

Page 49: Explanation of, Error messages, Explanation of error, Messages, Troubleshooting & repair, Diagnostic routines and error codes, Caution

Advertising
background image

F-10

TROUBLESHOOTING & REPAIR

F-10

IDEALARC CV-300

The CV-300 Meter PC Board displays error codes
when certain trouble conditions exist. The error codes,
trouble conditions and possible remedies are listed
below.

If, after attempting the remedies listed above, the error
condition still exists, the problem may be with the
wiring in the following areas: the shunt (leads 218 and
219), or voltage feedback (leads 213B, 214B, and
224B).

ERROR

CODE

E00

E10

E20

E30

E40

E50

E60

TROUBLE

1.

Output short circuited.

2.

May be encountered while starting or
welding with 1/16” aluminum wire.

Thermostat circuit has opened.

Memory error.

1.

Voltage Adjust potentiometer not
connected.

2.

Remote Control not functioning cor-
rectly.

Input line voltage too low.

Input line voltage too high.

Overload condition.

1.

Turn power off. Remove short cir-
cuit.

2.

(a) Turn power off to clear error.

Use recommended wfs, volt-
age settings and angle of
approach of wire to work.

(b) If problem persists, call Lincoln

Authorized Field Service
Facility.

Allow machine to cool. Be sure to pro-
vide adequate ventilation to machine.

Perform

Main Transformer Test to

verify PC Board input voltages.
Control Board may be faulty.

1.

Check wiring between Voltage
Adjust and the Control PC Board.

2.

See

Troubleshooting Guide

(Function Problems).

Turn Power off. Insure machine input
voltage is within specifications. Turn
power back on.

Turn Power off. Insure machine input
voltage is within specifications. Turn
power back on.

Reduce load on machine.

REMEDY

DIAGNOSTIC ROUTINES AND ERROR CODES

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-
383-2531 or 1-800-833-9353

CAUTION

Advertising