F-44

TROUBLESHOOTING & REPAIR

F-44

IDEALARC CV-300

PROCEDURE

1.

Disconnect main AC input power to
the machine.

2.

Remove the Case Roof and Sides.

3.

Remove the three screws from the
bottom of the Case Back Panel
using a 5/16" nutdriver. See Figure
F.25.

4.

Remove the two screws that attach
the reconnect panel to the Case
Back Panel. See Figure F.25.

5.

Remove that Case Back Panel.

6.

Label and cut the fan motor leads.

7.

Remove the four nuts, washers, and
lock washer which attach the fan
motor to the fan bracket. See figure
F.25.

8.

Remove the fan motor and blade
assembly carefully.

9.

Remove the fan blade from the
motor shaft using a Allen wrench.

FIGURE F.25 - Fan Motor removal.

FAN MOTOR AND FAN REMOVAL AND REPLACEMENT (CONTINUED)