The DC-655 can be used to power any of
the following Lincoln Wire feeders:

SEMI-AUTOMATIC WIRE FEEDERS

DH-10

LN-9*

LN-10

LN-9 GMA*

LN-7 GMA*

LN-23P

LN-742

LN-25

LN-7*

LN-8*

AUTOMATIC WIRE FEEDERS*

NA-3

NA-5R

NA-5

LT-7 Tractor

* European DC-655 models only provide 115VAC for these feeders at the ter-

minal strip (TS2)

CONNECTION OF LINCOLN ELECTRIC
AUTOMATIC OR SEMIAUTOMATIC WIRE
FEEDERS

ELECTRIC SHOCK can kill.

• Only qualified personnel should per-

form this installation.

• Turn the input power OFF at the dis-

connect switch or fuse box before working on this
equipment.

• Do not touch electrically hot parts.

Auxiliary power for wire feeder operation is available at
both a 14-pin MS receptacle and at terminal strips
with screw-type connections located on the front of
the machine. Refer to the Installation section for
pinouts and lead designations. The two circuits are
isolated, and each is protected by a circuit breaker.

The following descriptions show how to connect the
wire feeders using either the 14-pin MS receptacle or
the terminal strip.

AUTOMATIC WIRE FEEDERS

CONNECTING THE NA-3 OR LT-7 TO THE
IDEALARC DC-655 (TERMINAL STRIP)

1.

Set Idealarc DC-655 POWER toggle switch to the
OFF (0) position.

2.

Disconnect main AC input power to the Idealarc
DC-655.

3.

Connect the wire feeder control cable leads to the
Idealarc DC-655 terminal strip as shown in Figure
C.1.

4.

Connect the wire feeder control cable ground lead
to the frame terminal marked .

NOTE: The Idealarc DC-655 must be properly

grounded.

FIGURE C.1 – NA-3 OR LT-7 WIRE FEEDER

CONNECTION TO THE IDEALARC DC-655

5.

Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.

a.

Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connec-
tion with insulating tape.

b.

An S-16586- X remote voltage sensing work
lead is available for this purpose.

c.

Keep the #21 lead electrically separate from
the work cable circuit and connection.

d.

Tape the #21 lead to work cable for ease of
use.

ACCESSORIES

C-3

C-3

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

WARNING

NEGATIVE

POSITIVE

32

31

2

4

GND

21

ELECTRODE CABLE

TO WORK

POWER SOURCE

CONTROL BOX

21

FOR CONTROL CABLE
WITH 14 PIN

MS-TYPE

PLUG CONNECTOR

OR

FOR CONTROL CABLE

WITH TERMINAL STRIP

LEAD CONNECTORS

CONTROL CABLE

14-PIN

RECEPTACLE

75

76

77

TO AUTOMATIC

EQUIPMENT

TO AUTOMATIC

CONTROL CABLE

41 4 2 31 32

75 76 77

21

-

21

+

REMOTE VOLTAGE SENSING LEAD