Poor arc characteristics in all processes, Troubleshooting & repair, Caution – Lincoln Electric IDEALARC DC-655 User Manual

Page 53

Advertising
background image

TROUBLESHOOTING & REPAIR

F-11

F-11

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

WELDING PROBLEMS

Poor arc characteristics in all
processes.

1. Check the three-phase input

line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel.

2. Check the welding cables for

loose or faulty connections.

3. Make sure the proper welding

procedures are being used.
(Wire feed speed, arc voltage
and wire size)

4. Make sure the negative welding

cable is connected to the cor-
rect negative output terminal.
(Low or High inductance)

1. Check the weld mode switch

(SW2) and associated leads for
proper operation or loose or
faulty connections. See the
Wiring Diagram.

2. Perform the Firing Board Test.

3. Perform the SCR Bridge Test.

4. Perform the Main Transformer

Test.

5.

The control board may be
faulty. See the Control Board
LED Chart.

Poor arc striking with semiauto-
matic or automatic wire feeders.

1. Make sure the proper welding

procedures are being used.
(Wire feed speed, arc voltage
and wire size)

2. Check the welding cables for

loose or faulty connections.

1. Perform the Firing Board Test.

2. Perform the SCR Bridge Test.

3.

The control board may be
faulty. See the Control Board
LED Chart.