TROUBLESHOOTING & REPAIR

F-14

F-14

IDEALARC DC-655

ELECTRIC SHOCK

can kill.

• Do not touch electrically hot

parts.

TEST PROCEDURE

1. With the correct input power applied to the

DC-655 and the trigger circuit activated,
LED 10 on the firing board should be lit.
See Figure F.1. If LED 10 lights when the
trigger is activated, the wiring and circuitry
to the firing board is good. Perform the
Firing Board Test and see the Control
Board LED Chart.

See the Simplified

Trigger Diagram.

NOTE: LED 10 should not be lit if the trigger
circuit is not activated.

2. If LED 10 does not light when the trigger cir-

cuit is activated, proceed with the following
voltage and continuity checks.

3. Check the 10 Amp circuit breaker. It is the

one closest to the 115V duplex receptacle.
Reset if tripped.

WARNING

FIRING BOARD

G2699-[ ]

LED7

LED8

LED9

LED1

LED2

LED3

LED4

LED5

LED6

LED10

J5

J6

J7

J4

FIGURE F.1 – FIRING BOARD TRIGGER CIRCUIT TEST POINTS AND LEDS

INTERNAL TRIGGER CIRCUIT TEST (continued)