TROUBLESHOOTING & REPAIR

F-7

F-7

IDEALARC DC-655

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The 115 VAC receptacle is not
working. The machine’s welding
output is normal.

1. The circuit breaker may be

tripped. Reset if necessary.

2. Make sure the 115 VAC plug

and “load” is in good working
condition.

1. The circuit breaker may be

defective. Check associated
wiring. See the Wiring Diagram.

2. Check for 115 VAC at terminals

#31 and #32 on the terminal
strip. If 115 VAC is present at
the terminal strip, check the
wiring between the terminal
stirp, the circuit breaker and the
115 VAC receptacle. If 115 VAC
is NOT present at the terminal
strip, perform the Main
Transformer Test.

3.

The 115 VAC receptacle may
be defective.

When not welding for a period of
time, the machine shuts down.

1. This may be a normal condition.

See the Idle Shut Down Timer.