Theory of operation, General description – Lincoln Electric IDEALARC DC-655 User Manual

Page 38

Advertising
background image

GENERAL DESCRIPTION

The DC-655 is a three-phase, SCR controlled DC
power source. It is capable of either constant current
or constant voltage output. It is rated at 650 amps,
100% duty cycle with outstanding arc characteristics
for multiple welding processes.

INPUT LINE, CONTACTOR,
RECONNECT, FAULT PROTECTION
AND TRANSFORMERS

The desired three-phase input power is connected to
the DC-655 through an input contactor located in the
input box at the rear of the machine. Two phases of
the input line are also connected to the control trans-
former. The secondary of the control transformer sup-
plies 115 VAC power to the control board transformer
and to the input contactor through the fault protection
relay. The control board transformer supplies 42 VAC
to the control board.

A reconnect panel allows the user to configure the
machine for the desired input voltage. This three-
phase AC input is applied to the primary of the main
transformer. The transformer changes the high volt-
age, low current input power to a lower voltage, high-
er current output. The finishes or “neutrals” of the
main secondary coils are connected together, and the
six starts of the secondary windings are connected to
the rectifier assembly.

In addition, the main transformer also has eight isolat-
ed secondary windings. There are three 32 VAC wind-
ings, which provide power and “timing” to the firing
board. The 115 VAC winding powers the fan motor
and provides the user with up to 20 amps of 115 VAC
auxiliary power at the receptacle or 14-pin MS type
connector. The 42 VAC winding provides up to 10
amps at the 14-pin MS type connector. Three other
isolated coils are used to power the optional digital
meter PC board. One winding is rated at 42 VAC, and
the other two are each rated at 10 VAC.

THEORY OF OPERATION

E-2

E-2

IDEALARC DC-655

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE E.2 – INPUT LINE VOLTAGE, CONTACTOR, RECONNECT,

FAULT PROTECTION, MAIN AND CONTROL TRANSFORMERS

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

CONTROL

TRANSFORMER

R
E

C
O
N

N

E

C

T

CONTACTOR

FAULT PROTECTION

115VAC

MAIN

TRANSFORMER

CONTROL

BOARD

SHUNT

OUTPUT

CONTROL

MODE

SWITCH

POSITIVE

TERMINAL

NEGATIVE

TERMINAL

LATCHING

RESISTOR

F

E

E

D

B

A

C

K

F
E
E
D
B
A
C
K

SCR BRIDGE

42VAC

115VAC

42VAC

T
E
R

M

I

N

A

L

S

T
R
I
P

TO OPTIONAL

METER BOARD

HIGH

LOW

ARC FORCE

CONTROL

FIRING
BOARD

SNUBBER

FAN

BOARD

CR2

CONTROL
BOARD
TRANSFORMER

CR1

CHOKE

14-pin

Amphenol

115VAC

Receptacle

Fan

Motor

Fan

Thermal

Sensor

42VAC 10VAC10VAC

32VAC

32VAC

32VAC

SIGNAL

G

A
T
E

S

I

G

N
A

L

GATE SIGNAL

OUTPUT

CONTROL

Advertising