Accessories – Lincoln Electric IDEALARC DC-655 User Manual

Page 27

Advertising
background image

6.

Connect NA-5/-5R wire feeder control jumpers on
Voltage Control Board. See NA-5/-5R Operator’s
Manual.

NOTE: The connection diagram shown in Figure C.2

shows the electrode connected for positive
polarity. To change polarity:

a.

Set the Idealarc DC-655 POWER toggle
switch to the OFF (0) position.

b.

Move the electrode cable to the negative (-)
output terminal. (High inductance or low
inductance as needed).

c.

Move the work cable to the positive (+) output
terminal.

d.

If connecting lead #21 to the terminal strip,
connect it to the +21 terminal (to match work
polarity). If work polarity changes back to
negative, lead #21 must be connected to the -
21 terminal.

NOTE: For proper NA-5 operation, the electrode

cables must be secured under the clamp bar
on the left side of the NA-5 Control Box.

7.

Set the DC-655 OUTPUT CONTROL switch to the
“Remote” position and the OUTPUT TERMINALS
switch to the “Remote” position.